In
 the operation of brain stereotaxic devices, it is often necessary to 
perform microinjection on animals. An automatic microinjection pump is 
used, which is convenient to use. The syringe syringe is directly 
installed on the gripper, and the precise movement of the syringe piston
 is controlled by the microcomputer control driving unit to directly 
inject or recover liquids from experimental animals, avoiding errors 
caused by catheter methods.
M5258 high-precision microinjection pump,
 high-definition touch screen operation, Ditronstep micro step control 
system, used for precise control and delivery of trace liquid drugs or 
solutions. It is usually used in conjunction with brain locators or 
microcontrollers in the medical field, especially in clinical medicine, 
laboratory research, and drug development. This injection pump is 
compatible with most imported and domestic microinjectors (0.5ul 
-1000ul), with a stroke resolution of 0.190 μ m/μ step, a linear 
velocity range of 0.12 μ m/min to 121.92mm/min (flow rate=linear 
velocity x syringe loading area), and a propulsion distance of 70mm.
Technical Parameter
1. Working mode: infusion, extraction, infusion/extraction, extraction/infusion, continuous, multiple infusion
2. Touch display: 800 * 480 5-inch high-definition touch screen, easy to operate, clear and concise information
3. Language types: Chinese and English, 2 languages to choose from
4. Maximum travel: 70mm
5. Travel control accuracy: error ≤ ± 0.1%
6. Sample injector specifications: 0.5 μ L to 1000 μ L
7. Linear thrust: ≥ 25N
8. Linear speed range: 0.12 μ m/min to 121.92mm/min
Step resolution: 0.190 μ m/μ step
10. Online speed regulation: The current flow rate can be adjusted during operation
11. Calibration function: Supports syringe calibration and stores calibration coefficients
12.
 Syringe selection: Built in from major domestic and foreign 
manufacturers, with a choice of main models of syringes and support for 
customization
13. Parameter settings: Liquid volume, flow rate, 
infusion time, extraction time, interval time, and infusion frequency 
can be set and stored
14. Prompt function: Real time display of available maximum/minimum flow rate; Dynamically display operating parameters
15. Reminder function: When running to the set target liquid volume, sound an alarm prompt
16. Thrust setting: Suitable thrust can be set according to the specifications of the injector
17.
 External control function: Start stop control is controlled by external
 signals or contacts, with control modes of high level (5-24V), low 
level, and pulse selectable
18. Foot switch: 6.35 foot switch socket, which enables start stop control through the foot switch,
19. Communication control: RS485/USB optional, touch settings for address and baud rate
20. Status output: start stop, direction
21. Applicable power supply: AC 90V~264V 50/60Hz
22. Working environment: Temperature: 0-40 ℃ Humidity: Humidity 20% -80% RH No condensation
23. Storage environment: Temperature: -10~60 ℃ Humidity: 20% -80% RH No condensation
24. Protection level: IP31
25. Product size (mm): Controller: 240 * 149 * 87.5 (mm) Execution structure: 163 * 34 * 34 (mm)
Applicable Syringes
| Optional syringe capacity | Inner diameter of syringe(mm) | Reference flow range(nL/min-mL/min) | Optional syringe capacity | Inner diameter of syringe(mm) | Reference flow range(nL/min-mL/min) | 
| 0.5ul | 0.103 | 0.0007~0.0013 | 250ul | 2.304 | 0.3335~0.6671 | 
| 1ul | 0.146 | 0.0013~0.0027 | 500ul | 3.256 | 0.6658~1.3322 | 
| 2ul | 0.206 | 0.0027~0.0053 | 1ml | 4.73 | 1.4060~2.8110 | 
| 5ul | 0.343 | 0.0074~0.0148 | 2ml | 8.92 | 4.9990~9.9980 | 
| 10ul | 0.485 | 0.0148~0.0295 | 2.5ml | 8.92 | 4.9990~9.9980 | 
| 25ul | 0.729 | 0.0334~0.0668 | 5ml | 12.4 | 9.6620~19.3220 | 
| 50ul | 1.03 | 0.0667~0.1333 | 10ml | 14.87 | 13.8940~27.7860 | 
| 100ul | 1.457 | 0.1334~0.2668 | 
Ordering Information